INSTRUCTIONS FOR THE INSTALLER

INSTALLATION

Installing the top

The appliance is designed to be embedded into heat-resistant pieces of furniture. The walls of the pieces of furniture must resist a temperature of 75°C besides the room one. The equipment must not be installed near inflammable materials, such as curtains, cloths, etc. Make a hole in the top of the piece of furniture, with the dimensions indicated in fig. 3, keeping a distance of at least 50 mm between the rear edge of the installed device and 100 mm from the adjacent side walls. • If the hob is going to be installed on the top of an oven, precautions must be taken to guarantee an installation in accordance with current accident prevention standards. Pay particular attention to the position of the electric cable and gas pipe: they must not touch any hot parts of the oven. • Moreover, if the hob is going to be installed on the top of a built in oven without forced cooling ventilation, proper air vents must be installed to guarantee an adequate ventilation, with the lower air entering with a cross section of at least 200cm2, and the higher air exiting with a cross section of at least 60 cm2. Fastening the top Every cook-top is equipped with a special washer. A set of hooks is also supplied for mounting the cook-top. Depending on the type of mounting surface, the suitable type of mounting hook is supplied (hook A or hook B). For the installation proceed as follows:

  • Remove the racks and burners from the top.
  • Turn the appliance upside down and lay the washer S along the external border (fig. 5).
  • Introduce and place the cook-top in the hole made in the piece of furniture, then block it with the V screws of the fastening hooks G (fig.6 / 6A). Installation room This appliance is not provided with a device for exhausting the products of combustion. Regarding room ventilation rules where appliance is installed make reference to the legislation, in conformity with the local regulations. The room where the appliance is installed must have a minimum volume of 20m³ The influx of air must be through a permanent open-ing on the walls of the room and communicating with the outside. Ventilation can also come from an adjoining room, in this case respect the standards in force on this subject. The openings must have a minimum section of 200 cm². ATTENTION: The electrical connection of the cooking hob and the oven must be carried out separately for security issues and to allow easy removal of the oven from the unit FOR THE U.K. ONLY The room containing this hotplate should have an air supply in accordance with BS 5440: Part 2: 1989. All rooms require an openable window, or equivalent and some rooms will require a permanent vent a well. For room volumes up to 5 m³ an air vent of 100cm² is required. For room volumes between 5 m³ and 10 m³ an air vent of 50 cm² is required. If the room is greater than 5 m³ and has a door that opens directly to the outside, then no air vent is required. If there are other fuel burning appliances in the same room BS 5440: Part 2:1989 should be consulted to determine the air vent requirements. Gas connection Choose fixed connections or use a flexible pipe in stainless steel in compliance with the regulation in force. If you use flexible metallic pipes, be careful they do not come in touch with mobile parts or they are not squeezed. Also be careful when the hob is put together with an oven. ATTENTION: Make sure that the gas supply pressure of the appliance obeys the recomend-ed values If the supplied pressure has not the specified value, it is necessary to assemble a proper pressure regulator in compliance with the standard UNI EN 88. For Liquid Gas (LPG) the use of pressure regulator is allowed only if they are in compliance with UNI EN 12864. The adjustable connection is fixed to the comprehensive ramp by means of a threaded nut G 1/2". Screw the parts without force, adjust the connection inthe necessary direction and tighten everything (fig.7). Rigid connection: arry out connection by using met-al rigid pipes (copper with mechanical end) (UNI-CIG 7129). Flexible connection: Use a flexible pipe in stainless steel (UNI-CIG 9891) with a maximum length 2m. When installation is complete, make sure that the seal of each pipe fittingis correct. Use a soapy solution, not a flame

Was this article helpful?

0 out of 0 found this helpful

Didn’t find an answer to your question?