This article contains the manual for the BIK-97 by Boretti.
Boretti would like to congratulate you on your new kitchen purchase, and to thank you for choosing a Boretti brand product. Please read this manual carefully before going on to use the product. This will prevent possible problems and ensure that you are aware of the correct and safe use of this product In the event that queries arise once you have read the manual or at any time during the use of your Boretti product, we will be happy to help you. Please refer to the back cover of this manual for Boretti's contact details. We hope you enjoy the product! Electrical connection • The installation of this appliance and the connection to the electrical network should be entrus- ted only to an electrician perfectly to the fact of the normative regulations and which respects them scrupulously. • Protection against the parts under tension must be ensured after the builting-in. • The data of connection necessary are on the stickers place on the hob casing near the con- nection box. • The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking device with a contact opening of at least 3 mm. • The electrical circuit must be separated from the network by adapted devices, for example : circuit breakers, fuses or contactors. Caution! This appliance has only to be connected to a network 230 V~ 50 Hz. Connect always the earth wire. Respect the connection diagram. The connection box is located underneath at the back of the hob casing. To open the cover use a medium screwdriver. Place it in the slits and open the cover. Mains Connection Cable diameter Protection calibre 230V~1P+N 50Hz 1 Phase + N 3 x 2.5 mm² 25 A * 400V~2P+N 50Hz 2 Phases + N 4 x 1.5 mm² 16 A * 230V~2P+2N 50 Hz 2 Phases + 2N 5 x 1,5 mm² 16 A * (*) calculated with the simultaneous factor following standard TN 60 335-2-6/1990. Connecting the cooktop: For the various connections use the brass bridges which are in the terminal box. 1 phase 23 OV∼1F+N (not for the Netherlands!): Place a bridge between 1 and 2 then between 4 and 5. Attach the earthing to the “earth” terminal clamp, the neutral N to terminal clamp 4 or 5, and phase L to terminal clamp 1 or 2. 2 phases 400V~2F+N: Place a bridge between 4 and 5. Attach the earthing to the “earth” terminal clamp, the neutral N to terminal clamp 4 or 5, phase L1 to terminal clamp 1 and phase L2 to terminal clamp 2. 2 phases 23 OV~2F+2N: Place a bridge between 2 and 3. Connect the earthing to the “earth” terminal clamp, neutral N1 to terminal clamp 4, neutral N2 to terminal clamp 5, phase L1 to clamp 1 and phase L2 to clamp 2. Caution! ensure that you : correctly attach the wires and the bridges. Tighten the screws properly. Before making the connection, we strongly advise you to locate the phase(s), neutral and earth on the mains. If you have any doubts, call your electrician. Note: the bridges between terminals 4-5 and between terminals 1-2 were installed during the factory check. We cannot be held responsible for any incident resulting from incorrect connection or which could arise from the use of an ap- pliance which has not been earthed or has been equipped with a faulty earth connection.