This article explains how to assemble the SH RANGE by Boretti.
Installation
The extractor must be installed at least 65 cm above the cooking surface. If the installation instructions of the cooking appliance specify a greater distance, this must be taken into ac- count. Fit the extractor in such a way that it will be easy to remove from the wall without causing any damage. Removal may be neces- sary for future service operations. The extractor must be connected to an extrac- tion duct with a minimum diameter of 150 mm. This is very important to ensure the life and ex- traction capacity of your extractor. Extraction The extraction duct must be connected directly to the motor housing. When fitting the extrac- tion duct, make sure that the one-way valve is not blocked! We recommend fitting the duct with tape and not with screws. It is advisable to keep the duct as short as pos- sible, with as few bends as possible. It is also advisable to use a smooth duct in order to keep resistance to the minimum. This is extremely important for the best operation of your ex- tractor. Note: No ducting is supplied with the extrac- tor. If it is not possible to vent the steam outside, the extractor can be used in the filter mode F (recirculation) by fitting carbon filters. The filtered air is returned to the kitchen through the openings on the side of the chimney.